* MAX951 Op Amp Open-Loop Gain Response Test Circuit. * 951OL.CIR XAR1 1 2 101 3 4 235 97 197 MAX951 * Amp+ Amp- Comp+ Vdd Vss Ref Ampout Compout VP 3 0 5V VN 4 0 -5V vin 1 0 ac 1 VSHORTIN 0 101 0V VREFTEST 2 0 0V RLOAD97 97 0 100k RLOAD197 197 0 1MEG .OPTIONS RELTOL=.01 .ac dec 10 1 500k .PROBE .LIB MAX951.FAM .END