MAX6709, MAX6714
Low-Voltage, High-Accuracy, Quad Voltage Monitors in µMAX Package


  QuickView     Technical Documents     Ordering Info     More Information     User Comments (0)     All  
Status
Active: In Production.

Data Sheet
FULL DATA SHEET (PDF, 324kB)
Download this datasheet in PDF formatDownload   Send this datasheet to any email addressE-Mail


Description
The MAX6709/MAX6714 quad voltage monitors provide accurate monitoring of up to four supplies without any external components. A variety of factory-trimmed threshold voltages and supply tolerances are available to optimize the MAX6709/MAX6714 for specific applications. The selection includes input options for monitoring 5.0V, 3.3V, 3.0V, 2.5V, and 1.8V voltages. Additional high-input-impedance comparator options can be used as adjustable voltage monitors, general-purpose comparators, or digital-level translators.

The MAX6709 provides four independent open-drain outputs with 10µA internal pullup to VCC. The MAX6714 provides an active-low, open-drain active-low RESET output with integrated reset timing and three power-fail comparator outputs.

Each of the monitored voltages is available with trip thresholds to support power-supply tolerances of either 5% or 10% below the nominal voltage. An internal bandgap reference ensures accurate trip thresholds across the operating temperature range.

The MAX6709 consumes only 35µA (typ) of supply current. The MAX6714 consumes only 60µA (typ) of supply current. The MAX6709/MAX6714 operate with supply voltages of 2.0V to 5.5V. An internal undervoltage lockout circuit forces all four digital outputs low when VCC drops below the minimum operating voltage. The four digital outputs have weak internal pullups to VCC, accommodating wire-ORed connections. Each input threshold voltage has an independent output. The MAX6709/MAX6714 are available in a 10-pin µMAX® package and operate over the extended (-40°C to +85°C) temperature range.

Key Features   Applications/Uses
  • Monitor Four Power-Supply Voltages
  • Precision Factory-Set Threshold Options for 5.0V, 3.3V, 3.0V, 2.5V, and 1.8V (Nominal) Supplies
  • Adjustable Voltage Threshold Monitors Down to 0.62V
  • High-Accuracy (±2.0%) Adjustable Threshold Inputs
  • Low Supply Current
    • MAX6709: 35µA
    • MAX6714: 60µA
  • Four Independent, Active-Low, Open-Drain Outputs with 10µA Internal Pullup to VCC
  • 140ms (min) Reset Timeout Period (MAX6714 only)
  • 2.0V to 5.5V Supply Voltage Range
  • Immune to Supply Transients
  • Fully Specified from -40°C to +85°C
  • Small 10-Pin µMAX Package

 
  • Computers: Desktop, Workstation, Server
  • Data Storage Equipment
  • High-End Printers
  • Multivoltage Systems
  • Network Equipment
  • Servers
  • Telecommunications

    Key Specifications:  Supervisors (4 Monitored Voltages)
    Part Number Interface Reset Thresh.
    (V)
    Reset Out tRESET Watchdog Feature Supervisor Features Reset Thresh. Accur.
    (%)
    ICC
    (µA)
    Price
    Active Low min @ +25°C max See Notes
    MAX6709 
    Factory Fixed
    R/C Adjustable
    0 to 1.2
    1.2 to 1.8
    1.8 to 2.5
    2.5 to 3.3
    3.3 to 5.5
    Open Drain <1ms No Watchdog Adjustable Reset Input 2.5 50 $2.50 @1k
    MAX6714  85ms to 300ms
    Adjustable Reset Input
    Manual Reset
    Power Fail Comparator/Low Battery Detect
    90 $2.50 @1k
    See All Supervisors (4 Monitored Voltages) (26)

    Diagram
    MAX6709: Typical Operating Circuit
    Typical Operating Circuit

    MAX6714: Typical Operating Circuit
    Typical Operating Circuit

    Application Notes
  • Application Note 2853: Supervisors in Multivoltage Systems - MAX6709, MAX6714, MAX6714

    Design Guides
  • Microprocessor Supervisory (PDF)

    Reliability Reports
  • Show FIT data for:
  • Request Reliability Report for:

    Software/Models
    none

    Ordering Information
    Notes:

    1. Other options and links for purchasing parts are listed at: http://www.maxim-ic.com/sales.
    2. Didn't Find What You Need? Ask our applications engineers. Expert assistance in finding parts, usually within one business day.
    3. Part number suffixes: T or T&R = tape and reel;+ = RoHS/lead-free;# = RoHS/lead-exempt. More: SeeFull Data Sheet or Part Naming Conventions.
    4. * Some packages have variations, listed on the drawing. "PkgCode/Variation" tells which variation the product uses. Note that "+", "#", "-" in the part number suffix describes RoHS status. Package drawings may show a different suffix character.


    Devices: 1-76 of 76

    MAX6709 Free
    Sample
    Buy Status
    Package: TYPE PINS FOOTPRINT
      DRAWING CODE/VAR *
    Temp RoHS/Lead-Free?
    Materials Analysis
    MAX6709OUB-TG05    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709OUB-G05    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709AUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709AUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709BUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709BUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709CUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709CUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709DUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709DUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709EUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709EUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709FUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709FUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709GUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709GUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709HUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709HUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709IUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709IUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709JUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709JUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709KUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709KUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709LUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709LUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709MUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709MUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709NUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709OUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709OUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709PUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709QUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6709MUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709MUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709DUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709DUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709EUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709EUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709AUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709AUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709BUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709BUB+T    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709CUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709CUB+T    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709FUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709FUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709GUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709GUB+T    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709IUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709IUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709JUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709JUB+T    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709KUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709KUB+T    
    Active

    Land Pattern: Not Available

    -40°C to +85°C See data sheet
    MAX6709LUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709LUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709NUB+    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709OUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6709OUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714 Free
    Sample
    Buy Status
    Package: TYPE PINS FOOTPRINT
      DRAWING CODE/VAR *
    Temp RoHS/Lead-Free?
    Materials Analysis
    MAX6714AUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714AUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714BUB    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714BUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714CUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714CUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714DUB  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714DUB-T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10-2*
    -40°C to +85°C RoHS/Lead-Free: No
    Materials Analysis
    MAX6714AUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714AUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714BUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714BUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714CUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714CUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714DUB+  
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis
    MAX6714DUB+T    
    Active µMAX;10 pin;15 mm²
    Outline Drawing: 21-0061 (PDF)
    Land Pattern: 90-0330 (PDF)
    Use pkgcode/variation: U10+2*
    -40°C to +85°C RoHS/Lead-Free: Lead Free
    Materials Analysis

    More Information
  • New Product Press Release 2002-04-25 

    Related Products
    MAX6338 Quad Voltage Monitor with Four Outputs in µMax Package
    MAX6339 Quad Voltage µP Supervisory Circuit in SOT Package

    More Like This: View Product Families for Similar Products

    Didn't Find What You Need?
  • Next Day Product Selection Assistance from Applications Engineers
  • Parametric Search
  • Applications Help
  •  QuickView   Technical Documents   Ordering Info   More Information  
     Description 
     Key Features 
     Applications/Uses 
     Key Specifications 
     Diagram 

     Data Sheet 
     Application Notes 
     Design Guides 
     Engineering Journals 
     Reliability Reports 
     Software/Models 
     Evaluation Kits 

     Price and Availability 
     Samples 
     Buy Online 
     Package Information 
     Lead-Free Information 

     Related Products 
     Notes and Comments 
     Evaluation Kits 

    Document Ref.: 19-2379; Rev 1; 2006-05-09
    This page last modified: 2009-11-02


            •         •         •     Privacy Policy     •     Legal Notices

        Copyright © 2009 by Maxim Integrated Products