Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... connected to the switch. Relay Bounce. Relays are also represented as ideal
switching devices
in textbooks. Like the switching contacts ...
korea.maxim-ic.com/appnotes.cfm/an_pk/764 - 51k
Circuit Removes Relay-Contact Bounce - Maxim [Open results in new window]
... relay removes relay-contact bounce and reduces inrush current. Advances in
semiconductor technology
have allowed ICs to replace many mechanical relays, but ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3743 - 20k
Analog Switch Lowers Relay Power Consumption - Maxim [Open results in new window]
... Abstract: Design idea outlining a method to use an analog switch and discrete
components to reduce the power
dissipated in relay actuation. Relays are often ...
korea.maxim-ic.com/appnotes.cfm/an_pk/956 - 22k
Relay Driver Requires Only 25% Power - Maxim [Open results in new window]
... The table below shows the measured charge-pump performance, in terms of the total
voltage across the relay,
for 400Ω, 180Ω, and 90Ω 6V relays: ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2025 - 21k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... connected to the switch. Relay Bounce. Relays are also represented as ideal
switching devices
in textbooks. Like the switching contacts ...
korea.maxim-ic.com/appnotes.cfm/an_pk/764/ - 51k
Power-Save Mode Reduces Power Consumption When Driving Relays ... [Open results in new window]
... The power-save feature of the MAX4822/MAX4824 relay drivers allows a significant
reduction in the power
consumed by monostable relays when in the ON state. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3951 - 26k
Built-In Features Eliminate the Need for External Relays when ... [Open results in new window]
... relay, DUT, force and sense. 관련 부품. APP 3379: Dec 10, 2004. ... 애플리케이션 노트
3379. Built-In Features
Eliminate the Need for External Relays when ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3379 - 22k
Hitless Protection Switching with 1+1 Redundancy - Maxim [Open results in new window]
... There are three notable disadvantages to using relays. Firstly, relay switching
times are slow,
which causes data corruption on the line. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/388 - 31k
Using the MAXQ3212 Microcontroller as an AC-Power Sequencer ... [Open results in new window]
... The current to the relays' coil is switched using small (TO92 package) power FETs,
and the ...
system, a single FET was used between the port pin and the relay coil ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3914 - 27k
T1/E1/J1, N+1 Redundancy With Analog Switches - Maxim [Open results in new window]
... Relays, Relay, Analog Switch. Board Space, 100mm 2, 15mm 2. Power Consumption, 140mW,
5µW. Switching
Speed, 4ms, 30ns. Reliability, Mechanical Operation, No Moving ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2857 - 32k
Switch Bounce and Other Dirty Little Secrets - Maxim [Open results in new window]
... Switches can do some really odd things. Most engineers learn this dirty little secret
soon after connecting
a switch or a relay to a digital system. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/287 - 36k
Low-Cost, 24V Industrial Controller Is ESD-Protected - Maxim [Open results in new window]
... Figure 1 incorporates PLC programmability with the low cost of relay control ... These
outputs
can easily drive process indicator lamps, isolation relays, and other ...
korea.maxim-ic.com/appnotes.cfm/an_pk/805 - 22k
Designing a Networked On/Off Switch Using the TINI Platform ... [Open results in new window]
... The TCP/IP network stack and local control capabilities needed to design
an IP-networked relay are provided
by the TINI platform. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2036 - 31k
How to Use the MAXQ3212 Microcontroller as a Digital Thermostat ... [Open results in new window]
... This simple system senses the ambient temperature, compares it to a user-input set
point, and switches an output
relay as a result of this comparison. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3965 - 38k
How to Use the MAXQ3212 Microcontroller as a Digital Thermostat ... [Open results in new window]
... This simple system senses the ambient temperature, compares it to a user-input set
point, and switches an output
relay as a result of this comparison. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3965/ - 38k
Redundancy Protection for T3/E3/STS-1 Networks - Maxim [Open results in new window]
... active devices, such as the DS315x line interface unit, as well as the relays and
local ... In
the event that Line Card N fails, the relay on the protect bus for ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2696 - 30k
Multiplexing JTAG Interface Pins on MAXQ Microcontrollers - Maxim [Open results in new window]
... As an example, suppose one of the port pins was used both for the TCK signal (when
used in JTAG/TAP mode) and
to control a relay (in GPIO mode). ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3966 - 27k
Self-Oscillating Contactor Driver Minimizes Hold Power - Maxim [Open results in new window]
... 핵심 단어: self oscillating, contact driver, hold power, step-down converter, solenoid,
switches, relays,
standby inverter, Allbright 2180-40B contactor. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1792 - 22k
Minimizing Short-Circuit Current Amplitude and Pulse Width When ... [Open results in new window]
... High-current mercury-displacement relays were expected to be the best method, but
the results were not
satisfactory. A 60A 600V mercury relay with specified ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2694 - 33k
케이블 손실의 영향 - Maxim [Open results in new window]
... unit, PMU, pin electronics, PE, cable compensation, drive-compare-load, DCL, dielectric
loss, skin effect,
return path loss, connector, relay, high, low ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4303 - 31k