Enter keywords or part number    



 
  All pages     Appnotes     Company     Products     Support  


1-Wire® Extended Network Standard - Maxim   [Open results in new window]
... can affect the 1-Wire timing specification ... extended-network devices have longer recovery
times, t REC ... The recovery-time specification for all devices (standard ...

korea.maxim-ic.com/appnotes.cfm/appnote_number/3925 - 35k

Determining the Recovery Time for Multiple-Slave 1-Wire Networks ...   [Open results in new window]
... an extended recovery time of 2.5 times the minimum ... At standard speed the extended
recovery time prior to a ... The read/write timing diagram below consists of ...

korea.maxim-ic.com/appnotes.cfm/an_pk/3829 - 35k

Selection of Ultra-Fast Recovery Diodes Used in Flyback Circuits ...   [Open results in new window]
... This is known as the reverse recovery time (t rr ) of the diode. ... This will,
therefore, adversely affect the reverse recovery time. ...

korea.maxim-ic.com/appnotes.cfm/an_pk/849 - 42k

Understanding and Configuring the 1-Wire Timing of the DS2480B ...   [Open results in new window]
... as shown in Table 3. The longer t DSO is (alias t RECO for Write 0 times slots),
the more time is available for network recharge (recovery). ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4104 - 51k

Reading and Writing 1-Wire® Devices Through Serial Interfaces ...   [Open results in new window]
... that initiates digital communication, and on self-timed 1-Wire ... the impact of rise
and fall times on the 1 ... In the new style, the recovery time is included in the ...

korea.maxim-ic.com/appnotes.cfm/an_pk/74 - 61k

Small, High-Voltage Boost Converters - Maxim   [Open results in new window]
... rating and drain capacitance, and the diode's reverse-recovery time. ... inductor spends
1/nth of its time delivering energy ... voltage (V OUT ) is n times the input ...

korea.maxim-ic.com/appnotes.cfm/an_pk/1109/ - 42k

Choosing the Right 1-Wire® Master for Embedded Applications ...   [Open results in new window]
... In overdrive, the timing is approximately eight times faster than ... slaves in the
network without having to extend the recovery time between time ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4206 - 49k

Choosing the Right 1-Wire® Master for Embedded Applications ...   [Open results in new window]
... In overdrive, the timing is approximately eight times faster than ... slaves in the
network without having to extend the recovery time between time ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4206/ - 49k

Microchip PICmicro 마이크로컨트롤러와의 1-Wire 통신 ...   [Open results in new window]
... Parameter, Symbol, Min, Typ, Max, Units. Time Slot, t SLOT, 60, 120, µs. Recovery
Time, t REC, 1, µs. Write 0 Low Time, t LOW0, 60, 120, µs. Write 1 Low Time, t ...

korea.maxim-ic.com/appnotes.cfm/an_pk/2420 - 43k

소프트웨어를 통한 1-Wire® 통신 - Maxim   [Open results in new window]
... D,E,F,G,H,I,J; //-- Set the 1-Wire timing to 'standard ... Provide 10us recovery time. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/126 - 51k

An Efficiency Primer for Switch-Mode, DC-DC Converter Power ...   [Open results in new window]
... fast," and "ultra-fast" recovery diodes, with reverse-recovery time diminishing
as ... Schottky diodes offer virtually nonexistent recovery times and a V F that is ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4266 - 58k

Secure Supervisors Provide Multifaceted Monitoring to Ensure ...   [Open results in new window]
... a time reference for tamper-event recording and recovery. Time-of-day alarm and
CPU watchdog functions are also ... can be repeated any number of times until the ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4244 - 28k

SLIC Power-Supply Design - Maxim   [Open results in new window]
... necessary, because the breakdown voltage of Q1 is nine times' the voltage ... lower
switching frequency minimizes the impact of the reverse-recovery time on the ...

korea.maxim-ic.com/appnotes.cfm/an_pk/904 - 31k

Selecting a Serial Bus - Maxim   [Open results in new window]
... software drivers); "Determining the Recovery Time for Multiple-Slave 1-Wire
Networks." www.maxim-ic.com/AN3829 (recovery time); "Printed ...

korea.maxim-ic.com/appnotes.cfm/an_pk/3967 - 38k

Software Methods to Achieve Robust 1-Wire® Communication in ...   [Open results in new window]
... Wait 10µs for bus recovery time. ... Each time a bit is written to the bus, the bus state
is ... subroutine simply calls the bit-level routine eight times and returns ...

korea.maxim-ic.com/appnotes.cfm/an_pk/159 - 64k

Methods for Trimming the Power Required in RS-485 Systems - Maxim   [Open results in new window]
... is needed when the rise time of a signal is at least four times longer than ... forward
voltage V f , zero turn-on time t ON , and zero reverse-recovery time t rr ...

korea.maxim-ic.com/appnotes.cfm/an_pk/1090 - 39k

Glossary of Frequently Used High-Speed Data Converter Terms ...   [Open results in new window]
... Doubling the sampling frequency increases the signal-to-noise ratio by
3dB. Overvoltage Recovery Time. Overvoltage recovery time ...

korea.maxim-ic.com/appnotes.cfm/an_pk/740 - 38k

Glossary of Frequently Used High-Speed Data Converter Terms ...   [Open results in new window]
... Doubling the sampling frequency increases the signal-to-noise ratio by
3dB. Overvoltage Recovery Time. Overvoltage recovery time ...

korea.maxim-ic.com/appnotes.cfm/an_pk/740/ - 38k

Overview of the MAX11040 24-Bit Simultaneous-Sampling, Sigma-Delta ...   [Open results in new window]
... There is a similar recovery time before the signals return high. Figure 4.
High-frequency analog input OV detection and recovery for a fast-moving input. ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4272 - 27k

Regain Location Information by Leveraging the 1-Wire® Chain ...   [Open results in new window]
... Speed The fast timing of overdrive speed is not suited to operate a 1 ... network,
particularly if using a parasitic power supply, extended recovery time is required ...

korea.maxim-ic.com/appnotes.cfm/an_pk/4037 - 38k

Result Page:   1   2   3   4   5   6   7   8   9   10   Next


        •         •         •     Privacy Policy     •     Legal Notices

    Copyright © 2009 by Maxim Integrated Products