New CCII Current Conveyor - Maxim [Open results in new window]
... The output impedance of Z can be improved by adding in a cascode to M7/M8
if necessary. One must
be aware that to mimic the current ...
www.maxim-ic.com/appnotes.cfm/appnote_number/4198 - 32k
Secondary-Side Transformer Termination Improves Gain Flatness in ... [Open results in new window]
... Dynamic Performance and Excellent Gain Flatness in High-Speed ADC.") In high-IF
applications, the location
of the termination impedance becomes particularly ...
www.maxim-ic.com/appnotes.cfm/appnote_number/2884 - 29k
Tech Tips: Getting the Most from Your Sensor and Conditioning ... [Open results in new window]
... Buffer the power input with a low-impedance resistor and capacitor as close to the ...
A 10-ohm
resistor and a 0.1_F capacitor will greatly reduce the effects of ...
www.maxim-ic.com/appnotes.cfm/appnote_number/637 - 39k
Advantages of AC-Coupling in SerDes Applications - Maxim [Open results in new window]
... An internal reference voltage, often 1.2V, biases two high-impedance termination
resistors. ...
The load impedance is usually a 100Ω differential on both ends. ...
www.maxim-ic.com/appnotes.cfm/appnote_number/4085 - 30k
Using a DS1802 Push-Button Digital Potentiometer to Create an ... [Open results in new window]
... The last critical component is that the two R1 resistors should be relatively large
or the AC input impedance
will be too low for practical use. ...
www.maxim-ic.com/appnotes.cfm/appnote_number/161 - 42k
Impedance Matching and the Smith Chart: The Fundamentals - Maxim [Open results in new window]
... The objective is to match a source impedance (Z S ) to a load (z L ) at
the working frequency
of 60MHz (see Figure 11). The network ...
www.maxim-ic.com/appnotes.cfm/an_pk/742 - 50k
Advanced 1-Wire Network Driver - Maxim [Open results in new window]
... To adapt this driver to a different impedance, R1 and R2 need to be changed ... DS1921H,
High
Resolution Thermochron iButton Range H: +15°C to +46°C; Z: -5°C to ...
www.maxim-ic.com/appnotes.cfm/appnote_number/244 - 54k
Converting S-Parameters from 50Ω to 75Ω Impedance - Maxim [Open results in new window]
... Z O is usually a real impedance. ... 1 to obtain an input impedance (Z IN )
expression
Eq. 2, Replace the S 11 with R + jX, Multiply the denominator of Eq. ...
www.maxim-ic.com/appnotes.cfm/an_pk/2866/ - 22k
Impedance Matching and the Smith Chart: The Fundamentals - Maxim [Open results in new window]
... The objective is to match a source impedance (Z S ) to a load (z L ) at
the working frequency
of 60MHz (see Figure 11). The network ...
www.maxim-ic.com/appnotes.cfm/an_pk/742/ - 50k
Converting S-Parameters from 50Ω to 75Ω Impedance - Maxim [Open results in new window]
... Z O is usually a real impedance. ... 1 to obtain an input impedance (Z IN )
expression
Eq. 2, Replace the S 11 with R + jX, Multiply the denominator of Eq. ...
www.maxim-ic.com/appnotes.cfm/an_pk/2866 - 22k
[PDF] Converting S-Parameters from 50 Ω to 75 Ω Impedance [Open results in new window]
... Z O is usually a real impedance. For the sake of simplicity, input return loss
(S 11 ) will be
... Rearrange Eq. 1 to obtain an input impedance (Z ...
pdfserv.maxim-ic.com/en/an/AN2866.pdf
Ultra-Low-Cost, Medium Impedance RF Probe Is Rugged and Wideband ... [Open results in new window]
... APPLICATION NOTE 3699. Ultra-Low-Cost, Medium Impedance RF Probe Is Rugged and Wideband. ...
This ensures low impedance relative to the resistor value. ...
www.maxim-ic.com/appnotes.cfm/an_pk/3699 - 20k
[PDF] Ultra-Low-Cost, Medium Impedance RF Probe Is Rugged and Wideband ... [Open results in new window]
... Dec 22, 2005 APPLICATION NOTE 3699 Ultra-Low-Cost, Medium Impedance RF Probe Is
Rugged and Wideband
... This ensures low impedance relative to the resistor value. ...
pdfserv.maxim-ic.com/en/an/AN3699.pdf
MAX12557 Schematic and Layout Suggestions - Maxim [Open results in new window]
... In this mode REF_P, REF_N, and COM_ are high impedance inputs that accept the external ...
in
layer X, all digital outputs on layer Y, all clocks on layer Z, etc. ...
www.maxim-ic.com/appnotes.cfm/appnote_number/3558 - 53k
[PDF] Reduced Termination Loss by Active Synthesis of Output Impedance ... [Open results in new window]
... Practically, R SET may be fixed at a value 10x the nominal impedance to be measured.
The ratio of E1
and E2 then leads to the value of "Z OUT ." ...
pdfserv.maxim-ic.com/en/an/AN3390.pdf
IAR EWMAXQ 4.0 Linker File—Simplified - Maxim [Open results in new window]
... Refer now back to the first line in Block 4: -Z(DATA)DATA16_C,DATA8_ID,DATA16_ID,
CHECKSUM,CONST=8100-FFFF
/* in bytes */ This line indicates where the ...
www.maxim-ic.com/appnotes.cfm/appnote_number/4128 - 38k
Reduced Termination Loss by Active Synthesis of Output Impedance ... [Open results in new window]
... R SET / 9 Practically, R SET may be fixed at a value 10x the nominal impedance to
be measured. The ratio
of E1 and E2 then leads to the value of "Z OUT ." If ...
www.maxim-ic.com/appnotes.cfm/an_pk/3390 - 37k
[PDF] Impedance Matching and the Smith Chart: The Fundamentals - AN742 [Open results in new window]
... The objective is to match a source impedance (Z ... A second example matches the output
of the MAX2472 with a 50Ω load impedance (z L ) at the working frequency ...
pdfserv.maxim-ic.com/en/an/AN742.pdf
[PDF] General Network Interface Design Criteria for the DS2153 and ... [Open results in new window]
... Matching source impedance to the characteristic impedance of the line prevents ... L1
L0 Application Transformer N Return Loss ¹ Z Rt ² 0 0 0 75 ohm normal 1.15 ...
pdfserv.maxim-ic.com/en/an/AN352.pdf
General Network Interface Design Criteria for the DS2153 and ... [Open results in new window]
... Matching source impedance to the characteristic impedance of the line prevents ... L1,
L0, Application, Transformer N, Return Loss¹, Z Rt ². 0, 0, 0, 75 ohm normal, ...
www.maxim-ic.com/appnotes.cfm/an_pk/352 - 24k