Compensating for Ideality Factor and Series Resistance Differences ... [Open results in new window]
... Some newer CPU thermal sense diodes have lower ideality factors. To use a CPU optimized
for an ideality
factor of 1.008 with a CPU that has an ideality factor ...
www.maxim-ic.com/appnotes.cfm/an_pk/1057 - 33k
[PDF] Compensating for Ideality Factor and Series Resistance Differences ... [Open results in new window]
... Some newer CPU thermal sense diodes have lower ideality factors. To use a CPU optimized
for an ideality
factor of 1.008 with a CPU that has an ideality factor ...
pdfserv.maxim-ic.com/en/an/AN1057.pdf
[PDF] Extended-Range Temperature-Sensing ICs - AN3178 [Open results in new window]
... ICs depends on clock speed, process, device package, and various design factors. ...
The ideality
factor of a two-lead diode is incompatible with remote-diode ...
pdfserv.maxim-ic.com/en/an/AN3178.pdf
Extended-Range Temperature-Sensing ICs - Maxim [Open results in new window]
... ICs depends on clock speed, process, device package, and various design factors. ...
The ideality
factor of a two-lead diode is incompatible with remote-diode ...
www.maxim-ic.com/appnotes.cfm/an_pk/3178 - 29k
[PDF] External Temperature Sensor Calibration for the MAX16031/MAX16032 ... [Open results in new window]
... constants, the diode ideality factor, and the ratio of the two ... sensing circuitry
requires
calibration to compensate for different diode ideality factors. ...
pdfserv.maxim-ic.com/en/an/AN4284.pdf
External Temperature Sensor Calibration for the MAX16031/MAX16032 ... [Open results in new window]
... a ratio determined by physical constants, the diode ideality factor, and the ... circuitry
requires
calibration to compensate for different diode ideality factors. ...
www.maxim-ic.com/appnotes.cfm/an_pk/4284 - 35k
[PDF] Temperature Monitoring Using the MAX1253/54 and MAX1153/54 ... [Open results in new window]
... I LOW ) q = charge of electron = 1.602. 10 -19 Coulombs k = Boltzman's constant
= 1.38. 10 -23 J/K n =
ideality factor = 1 To make ...
pdfserv.maxim-ic.com/en/an/AN1944.pdf
Temperature Monitoring Using the MAX1253/54 and MAX1153/54 - Maxim [Open results in new window]
... 10 -23 J/K n = ideality factor = 1 To make temperature measurements using this method,
the device performs
two measurements using two separate constant current ...
www.maxim-ic.com/appnotes.cfm/an_pk/1944 - 27k
[PDF] Monitor Heat Dissipation in Electronic Systems by Measuring Active ... [Open results in new window]
... Because Θ JA depends on the layout and other physical factors in a ... part mismatch
is then
due to dispersion of the diode characteristics (the ideality factor). ...
pdfserv.maxim-ic.com/en/an/AN3500.pdf
Monitor Heat Dissipation in Electronic Systems by Measuring Active ... [Open results in new window]
... Because Θ JA depends on the layout and other physical factors in a ... part mismatch
is then
due to dispersion of the diode characteristics (the ideality factor). ...
www.maxim-ic.com/appnotes.cfm/an_pk/3500 - 40k
[PDF] Measuring Temperature with the MAX1358 Data Acquisition System ... [Open results in new window]
... voltage = 1.251V (typ) n = diode ideality = 1.000 (typ) k = Boltzmann's
constant = 1.3807 × 10 -23
Joules/Kelvin I 1 = Current ...
pdfserv.maxim-ic.com/en/an/AN4296.pdf
Measuring Temperature with the MAX1358 Data Acquisition System ... [Open results in new window]
... ADC reading with I 4 as current source V REF = ADC reference voltage = 1.251V (typ)
n = diode ideality
= 1.000 (typ ... Step 3. Calculate the Gain Correction Factor. ...