직렬 디지털 데이터 네트워크 - Maxim [Open results in new window]
... Transmission, LS bit first, half-duplex, MS bit first plus Acknowledge bit,
half-duplex,
MS bit first plus Acknowledge bit, half-duplex, MS bit first, full- ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3438 - 30k
직렬 디지털 데이터 네트워크 - Maxim [Open results in new window]
... Transmission, LS bit first, half-duplex, MS bit first plus Acknowledge bit,
half-duplex,
MS bit first plus Acknowledge bit, half-duplex, MS bit first, full- ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3438/ - 30k
RS-485 (EIA/TIA-485) Differential Data Transmission System Basics ... [Open results in new window]
... 핵심 단어: RS-485, RS485, RS-422, RS422, EIA/TIA-485, EIA/TIA-422, differential
data transmission, full-duplex,
half-duplex, unit load, fractional unit load ...
korea.maxim-ic.com/appnotes.cfm/an_pk/736/ - 27k
RS-485 (EIA/TIA-485) Differential Data Transmission System Basics ... [Open results in new window]
... 핵심 단어: RS-485, RS485, RS-422, RS422, EIA/TIA-485, EIA/TIA-422, differential
data transmission, full-duplex,
half-duplex, unit load, fractional unit load ...
korea.maxim-ic.com/appnotes.cfm/an_pk/736 - 27k
Explanation of Maxim RS-485 Features - Maxim [Open results in new window]
... Full/Half Duplex. ... This is referred to as "half duplex." A full-duplex system,
on
the other hand, would allow communications in both directions simultaneously. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/367 - 43k
Using RS-485/RS-422 Transceivers in Fieldbus Networks - Maxim [Open results in new window]
... PROFIBUS DP connects to the bus using half-duplex RS-485 transceivers, which
transfer data over
a single, shielded, twisted-pair cable. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1833 - 34k
Using RS-485/RS-422 Transceivers in Fieldbus Networks - Maxim [Open results in new window]
... PROFIBUS DP connects to the bus using half-duplex RS-485 transceivers, which
transfer data over
a single, shielded, twisted-pair cable. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1833/ - 34k
RS-485 Data Interface Gives Isolated, Full-Duplex Operation ... [Open results in new window]
... meters. IC2 is a complete half-duplex interface that includes transceivers,
optocouplers, a power
driver, and a transformer. The ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2116 - 24k
SPI/I²C Bus Lines Control Multiple Peripherals - Maxim [Open results in new window]
... Because 2-wire interfaces have only one data line, they can operate in half-duplex
mode only
(data can only be transmitted or received on a given cycle, but ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4024 - 43k
Using the MAX3157 High-CMR RS-485 Transceivers - Maxim [Open results in new window]
... For half-duplex two-wire RS-485 transmission, the internal receiver switch is set
as shown; and
a single 2-wire line is connected to terminals Y and Z ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1137 - 44k
Fundamentals of RS-232 Serial Communications - Maxim [Open results in new window]
... In half-duplex systems, this condition maintains the DCE in receive mode and disables
transmit
mode. ... Figure 5. Half-duplex communication scheme. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/83/ - 46k
Fundamentals of RS-232 Serial Communications - Maxim [Open results in new window]
... In half-duplex systems, this condition maintains the DCE in receive mode and disables
transmit
mode. ... Figure 5. Half-duplex communication scheme. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/83 - 46k
Implementing a Software UART on the MAXQ3210 - Maxim [Open results in new window]
... Since the MAXQ3210 only contains one general-purpose timer, the software UART will
be a half-duplex
implementation, which means that characters can only be ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4041 - 29k
Requirements of Remote Keyless Entry (RKE) Systems - Maxim [Open results in new window]
... The next development in RKE systems is 2-way (half-duplex) communications, which
first appeared
as the "passive RKE" already available in some high-end ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3395 - 39k
Methods for Trimming the Power Required in RS-485 Systems - Maxim [Open results in new window]
... That is, if the differential voltage on the RS-485 side of a half-duplex configuration
is 0V,
and no master transceiver is driving the line (or a connection ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1090 - 39k
Creating Networked Multimedia Applications with the DS80C400 ... [Open results in new window]
... Even on an old (half duplex) 10Mb network with an effective 5Mbps bandwidth,
the audio application uses
less than 4% of that bandwidth. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/711 - 37k
Overview of 1-Wire® Technology and Its Use - Maxim [Open results in new window]
... 1-Wire is the only voltage-based digital system that works with two contacts,
data and ground, for half-duplex
bidirectional communication. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1796 - 46k
Regain Location Information by Leveraging the 1-Wire® Chain ... [Open results in new window]
... The 1-Wire bus is a simple signaling scheme that performs half-duplex bidirectional
communications
between a host/master controller and one or more slaves ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4037 - 38k
How to Use Serial Peripheral Interface (SPI) on the MAXQ3180 ... [Open results in new window]
... byte and receives one byte. Some SPI peripherals sacrifice speed in favor
of simulating a half-duplex
operation. This is not the ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4246 - 29k
Choosing the Right 1-Wire® Master for Embedded Applications ... [Open results in new window]
... The 1-Wire bus is a simple signaling scheme that performs half-duplex bidirectional
communications
between a master controller and one or more slaves sharing a ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4206 - 49k