Using Lookup Tables to Perform Gamma Correction on LEDs - Maxim [Open results in new window]
... γ = gamma-correcting factor (ie, 2.5); counts is the number of timer steps between ...
Using equation 2 to apply gamma correction to the values above, yields the ...
www.maxim-ic.com/appnotes.cfm/an_pk/3667 - 22k
[PDF] Using Lookup Tables to Perform Gamma Correction on LEDs - AN3667 [Open results in new window]
... q γ = gamma-correcting factor (ie, 2.5) ... Using equation 2 to apply gamma correction
to the values above, yields the following values for T2C0 (Figure 2): ...
pdfserv.maxim-ic.com/en/an/AN3667.pdf
Programming 10-Bit Gamma Registers on the DS3514 - Maxim [Open results in new window]
... APPLICATION NOTE 4331. Programming 10-Bit Gamma Registers on the DS3514. Abstract:
The DS3514 ...
1100 0000 Programming the Gamma Data. Below ...
www.maxim-ic.com/appnotes.cfm/an_pk/4331 - 21k
Gamma-Photon Radiation Detector - Maxim [Open results in new window]
... Gamma-Photon Radiation Detector. Abstract: A PIN photodiode, four low-noise op amps
and a comparator
are used to detect individual photons of gamma radiation. ...
www.maxim-ic.com/appnotes.cfm/an_pk/2236 - 24k
[PDF] Programming 10-Bit Gamma Registers on the DS3514 - AN4331 [Open results in new window]
... APPLICATION NOTE 4331 Programming 10-Bit Gamma Registers on the DS3514 Abstract:
The DS3514 programmable
gamma and V ... The DS3514 programmable gamma and V ...
pdfserv.maxim-ic.com/en/an/AN4331.pdf
[PDF] Gamma-Photon Radiation Detector - AN2236 [Open results in new window]
... APPLICATION NOTE 2236 Gamma-Photon Radiation Detector ... The circuit of Figure 1 includes
a
PIN photodiode that detects individual photons of gamma radiation. ...
pdfserv.maxim-ic.com/en/an/AN2236.pdf
[PDF] Understanding Analog Video Signals - AN1184 [Open results in new window]
... video signal structure, video formats, standard video voltages, gamma correction,
scan rates ...
G', B', where the prime mark (') indicates gamma (γ) correction. ...
pdfserv.maxim-ic.com/en/an/AN1184.pdf
Understanding Analog Video Signals - Maxim [Open results in new window]
... video signal structure, video formats, standard video voltages, gamma correction,
scan rates ...
G', B', where the prime mark (') indicates gamma (γ) correction. ...
www.maxim-ic.com/appnotes.cfm/an_pk/1184/ - 55k
Understanding Analog Video Signals - Maxim [Open results in new window]
... video signal structure, video formats, standard video voltages, gamma correction,
scan rates ...
G', B', where the prime mark (') indicates gamma (γ) correction. ...
www.maxim-ic.com/appnotes.cfm/an_pk/1184 - 55k
[PDF] Using an Analog Voltage to Control a Digital Potentiometer ... [Open results in new window]
... 1. A nonlinear transfer function (eg, gamma correction) can be implemented by using
the DS3906 variable
resistor with the correct transfer function implemented ...
pdfserv.maxim-ic.com/en/an/AN4051.pdf
[PDF] Bias Supply Powers Low-Power Geiger-Mueller Tube - AN3757 [Open results in new window]
... event. Geiger-Mueller tubes are less sensitive to non-gamma-ray radiation,
and their dose-rate calibration
accuracy is poor. They ...
pdfserv.maxim-ic.com/en/an/AN3757.pdf
[PDF] LNA Optimized for GPS (REP024) - AN1985 [Open results in new window]
... CC . The input match to the LNA is set for a compromise between
gamma-opt and conjugate S11, for a -10dB
input return loss. The ...
pdfserv.maxim-ic.com/en/an/AN1985.pdf
[PDF] Measuring Differential Impedances with a Two-Port Network Analyzer ... [Open results in new window]
... This article describes how a two-port network analyzer is used to measure differential
impedance. Gamma
is calculated from the measured S-parameters. ...
pdfserv.maxim-ic.com/en/an/AN915.pdf
Measuring Differential Impedances with a Two-Port Network Analyzer ... [Open results in new window]
... This article describes how a two-port network analyzer is used to measure differential
impedance. Gamma
is calculated from the measured S-parameters. ...
www.maxim-ic.com/appnotes.cfm/an_pk/915 - 21k
[PDF] Impedance Matching and the Smith Chart: The Fundamentals - AN742 [Open results in new window]
... Page 2 of 18 Page 3. The Smith chart is a polar plot of the complex reflection
coefficient (also called gamma
and symbolized by Γ). ...
pdfserv.maxim-ic.com/en/an/AN742.pdf
Bias Supply Powers Low-Power Geiger-Mueller Tube - Maxim [Open results in new window]
... event. Geiger-Mueller tubes are less sensitive to non-gamma-ray radiation,
and their dose-rate calibration
accuracy is poor. They ...
www.maxim-ic.com/appnotes.cfm/an_pk/3757 - 21k
Impedance Matching and the Smith Chart: The Fundamentals - Maxim [Open results in new window]
... the circles. The Smith chart is a polar plot of the complex reflection
coefficient (also called gamma
and symbolized by Γ). Or, it ...
www.maxim-ic.com/appnotes.cfm/an_pk/742/ - 50k
Impedance Matching and the Smith Chart: The Fundamentals - Maxim [Open results in new window]
... the circles. The Smith chart is a polar plot of the complex reflection
coefficient (also called gamma
and symbolized by Γ). Or, it ...
www.maxim-ic.com/appnotes.cfm/an_pk/742 - 50k