Circuit Removes Relay-Contact Bounce - マキシム [Open results in new window]
... controller. An example of relay-contact bounce (Figure 2) shows three bounces
with an inrush
current peak of almost 30A. (The top ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3743 - 21k
Protecting Against Momentary Power Loss Due to Battery-Bounce ... [Open results in new window]
... Against Momentary Power Loss Due to Battery-Bounce. ... can cause momentary interruptions
when
batteries lose contact. ... the impact can open internal contacts for as ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3209 - 23k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... キーワード: switch debouncers, 15kV, ESD, switch protection ... Contact bounce is not
acceptable,
because automotive ... application note, "Switch Bounce and Other ...
japan.maxim-ic.com/appnotes.cfm/an_pk/764/ - 52k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... キーワード: switch debouncers, 15kV, ESD, switch protection ... Contact bounce is not
acceptable,
because automotive ... application note, "Switch Bounce and Other ...
japan.maxim-ic.com/appnotes.cfm/an_pk/764 - 52k
Semiconductor Toggle Switch - マキシム [Open results in new window]
... Power is delivered by circuitry rather than a pair of contacts that go straight
to the battery. Protection
can be provided against contact bounce and power ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3223 - 23k
[PDF] アプリケーションノート [Open results in new window]
... Initial Contact Contact Bounce Good Contact Poor contact >10ms Average of
100 contacts
using a shorted iButton Page 7. AN159 7 of 21 ...
pdfserv.maxim-ic.com/jp/an/AN159J.pdf
-48V Hot Swap Solution For Telecom Line Cards Assures Immunity To ... [Open results in new window]
... the controller holds power switch Q1 in the OFF state for 300ms, allowing time for
the card to be firmly in
place and connector-contact bounce to settle before ...
japan.maxim-ic.com/appnotes.cfm/an_pk/1881 - 35k
Switching Between Battery and External Power Sources ... [Open results in new window]
... First, contact bounce effects can occur when the external source is connected and
disconnected, resulting
in power spikes, as shown in Figure 2. Second, the ...
japan.maxim-ic.com/appnotes.cfm/an_pk/1136 - 24k
Manually Operated Digital Potentiometer Doesn't Need a ... [Open results in new window]
... microcontroller. To mask the effect of contact bounce in mechanical switches
S1 and S2, a dual switch
debouncer (IC1) is used. A ...
japan.maxim-ic.com/appnotes.cfm/an_pk/1118 - 22k
Where Is Ground? - マキシム [Open results in new window]
... In simple terms, as the switch starts opening on the +25V side, the contact
will bounce between
open circuit and being connected to +25V. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4292/ - 33k
Where Is Ground? - マキシム [Open results in new window]
... In simple terms, as the switch starts opening on the +25V side, the contact
will bounce between
open circuit and being connected to +25V. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4292 - 33k
Interfacing SD Cards with the TINI System - マキシム [Open results in new window]
... Error detection allows for robust error recovery in the event of physically induced
errors such as contact
bounce during insertion and removal or nonideal ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4068 - 36k
Pushbuttons Control Regulated Switching Converter - マキシム [Open results in new window]
... A time-delay network (R1, R2, and C1) masks the switch bounce on S1 that would ... pin
to ramp
slowly to 0V, thereby removing the effect of any bounce that occurs ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3535 - 22k
Single-Pushbutton ON/OFF Power Control - マキシム [Open results in new window]
... キーワード: pushbutton power switches, switch debouncers, LDO linear regulator,
flip-flops. ... The
normally open (NO) single-contact pushbutton connects to a ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4444 - 21k
Using a Keypad and LCD Display with the MAXQ2000 - マキシム [Open results in new window]
... Additionally, to prevent the bouncing contacts of a switch from registering multiple
presses, the application
requires that a key be held down for a certain ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3414 - 36k
SHA iButton Secrets and Challenges - マキシム [Open results in new window]
... the speed of a bar code target, time for an LCD display to issue READY status after
a character write, bounce
of a mechanical switch or relay contact, etc.); ...
japan.maxim-ic.com/appnotes.cfm/an_pk/152 - 36k
Design Considerations for Data-Lump Cables - マキシム [Open results in new window]
... 8kV, IEC 1000-4-2, Contact Discharge Method. ... the fault current goes to ground, the
ground
connection should be kept short to reduce the effects of ground bounce. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/739 - 42k
Design Considerations for Data-Lump Cables - マキシム [Open results in new window]
... 8kV, IEC 1000-4-2, Contact Discharge Method. ... the fault current goes to ground, the
ground
connection should be kept short to reduce the effects of ground bounce. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/739/ - 42k
The MAXQ Microcontroller in Action: Designing a Bicycle Computer ... [Open results in new window]
... measurements: a magnet passes over a reed switch and closes a contact, causing the ...
too close
to the sensor, making the whole DS2423 circuit bounce around a lot ...
japan.maxim-ic.com/appnotes.cfm/an_pk/3845 - 44k