DS2155 Internal BERT Programming - Maxim [Open results in new window]
... 애플리케이션 노트 389. DS2155 Internal BERT Programming. Abstract:
Application note ... Programming the
DS2155 BERT. Enable the BERT ...
korea.maxim-ic.com/appnotes.cfm/an_pk/389 - 24k
DS2172 BERT Interface to all Dallas Framers and Transceivers ... [Open results in new window]
... 애플리케이션 노트 334. DS2172 BERT Interface to all Dallas Framers and
Transceivers. ... Dallas Framer/SCT
And BERT Information. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/334 - 28k
How to Use the Bit-Error-Rate Tester (BERT) on the DS2652x STCs ... [Open results in new window]
... 핵심 단어: BERT, T1, E1, J1, Single Chip Transceiver (SCT). 관련 부품. ... How
to Use the Bit-Error-Rate
Tester (BERT) on the DS2652x STCs. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3968 - 29k
HFTA-05.0: Statistical Confidence Levels for Estimating BER ... [Open results in new window]
... 핵심 단어: BER, bit error ratio, P(e). 관련 부품. ... 애플리케이션 노트 1095. HFTA-05.0:
Statistical Confidence
Levels for Estimating BER Probability. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1095 - 19k
HFTA-10.0: Physical Layer Performance: Testing the Bit Error Ratio ... [Open results in new window]
... 애플리케이션 노트 3419. HFTA-10.0: Physical Layer Performance: Testing
the Bit Error Ratio (BER). Abstract:
This article reviews ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3419 - 18k
HFAN-03.0.1: Setting a LOP (Loss of Power) Threshold Level ... [Open results in new window]
... 애플리케이션 노트 460. HFAN-03.0.1: Setting a LOP (Loss of Power) Threshold
Level Equivalent to a BER Level
of 10-3. Abstract ...
korea.maxim-ic.com/appnotes.cfm/an_pk/460 - 23k
HFAN-04.0.2: Converting between RMS and Peak-to-Peak Jitter at a ... [Open results in new window]
... 핵심 단어: noise BER, RMS, peak to peak, jitter, random jitter. 관련 부품. ...
HFAN-04.0.2: Converting
between RMS and Peak-to-Peak Jitter at a Specified BER. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/462 - 21k
Bit Error Rate Testing the DS314x Series of DS3/E3 Framers - Maxim [Open results in new window]
... 핵심 단어: BERT, EBERT, OC-3, STS-1, EC-1, DS3, E3, framer, enhanced bit error
rate tester, DS3/E3 framers,
bit error rate testing. 관련 부품. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/2706 - 22k
Enabling Fractional-T1(FT1) Loopback Detection on the DS31256 ... [Open results in new window]
... applications. The DS31256 has only one BERT engine, but has 16 V.54 engines
(one per port). ...
4. Set Up the Pattern in BERT Register. void ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3818 - 25k
PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit - Maxim [Open results in new window]
... note details how to utilize the internal bit error-rate testing (BERT) feature of ...
the link
without requiring the system engineer to design a BER/PRBS system. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4254 - 38k
DS26303 Short-Haul Line Interface Unit vs. LXT384 - Maxim [Open results in new window]
... Built-in BERT tester for diagnostics. Not supported. ... 00h) Primary Bank AAh) Secondary
Bank
01h) Individual LIU Bank 02h) BERT Bank, Reserved. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3915 - 37k
시리얼라이저와 디시리얼라이저 페어, MAX9247 ... [Open results in new window]
... 비트 에러율 테스터(BERT)는 RGB 데이터상에서만 구현된다. ... 위해 각
케이블 길이에 대한 비트 에러율(BER)을 관찰하고 10분 ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3806 - 33k
DS26303 Short-Haul Line Interface Unit vs. IDT82V2048 - Maxim [Open results in new window]
... Requires that both receivers use the same front-end termination. Built in BERT tester
for diagnostics.
... 01, Individual LIU Bank, Yes, No. 02, BERT Bank, Yes, No. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3916 - 39k
Interfacing User Devices and the DST1E1DK SCT Design Kit - Maxim [Open results in new window]
... an 8051 processor-based microcontroller, on-board EPROM, a socket for testing different
Dallas Semiconductor
SCTs, and a DS2172 Bit Error Rate Tester (BERT). ...
korea.maxim-ic.com/appnotes.cfm/an_pk/375 - 23k
DS2172 Pattern Synchronization - Maxim [Open results in new window]
... 핵심 단어: BERT, DS2172, pattern, synchronization. ... Abstract: This application note
describes
the operation of pattern synchronization of the DS2172 BERT. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/333 - 21k
DS2172 Simplified Receiver Operation - Maxim [Open results in new window]
... 핵심 단어: DS2172, bit error rate tester, BERT. ... Abstract: DS2172 Bit Error Rate Tester
(BERT)
simplified receiver operation during repetitive pattern mode. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/332 - 18k
HFAN-03.0.0: Accurately Estimating Optical Receiver Sensitivity ... [Open results in new window]
... Abstract: In optical communication systems, sensitivity is a measure of how weak
an input signal can get before
the bit-error ratio (BER) exceeds some ...
korea.maxim-ic.com/appnotes.cfm/an_pk/607 - 21k
An Introduction to Jitter in Communications Systems - Maxim [Open results in new window]
... gaussian, random, RJ, deterministic, cycle to cycle, adjacent cycle, duty cycle
distortion, pulse width distortion,
inter-symbol, bit error rate, BER, ber. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1916 - 40k
[PDF] LOS Detection Comparison in Optical Receiver [Open results in new window]
... 모듈 설계자는 특정 비트 에러율(BER)에 대 한 신호손실 어서트
(assert) 임계값을 프로그 래밍할 수 있다. ...
pdfserv.maxim-ic.com/kr/an/AN3432K.pdf
Signal Integrity vs. Transmission Rate and Cable Length for LVDS ... [Open results in new window]
... to apply LVDS signaling to various applications but require familiarity with the
characteristics of LVDS on
the data rate, bit error rate (BER), cable length ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1856 - 39k