Maxim Leads the Way in ESD Protection - Maxim [Open results in new window]
... Figure 2. When discharged, this circuit (the Human Body ... 2 Compliance Level. Max Test
Voltage,
Contact Discharge (kV). Max Test Voltage, Air GAP Discharge (kV ...
korea.maxim-ic.com/appnotes.cfm/an_pk/639 - 53k
New RS-232 ICs Feature 1µA Supply Current, ±15kV ESD Protection ... [Open results in new window]
... body model and IEC 801-2 air-gap discharge method ESD (electrostatic discharge)
threatens
an ... The discharges accompanying these routine events can render an ...
korea.maxim-ic.com/appnotes.cfm/an_pk/654 - 53k
Practical Aspects of EMI Protection - Maxim [Open results in new window]
... and an electrode (shaped to simulate a finger) that discharges into the ... The test
specification
distinguishes between contact discharge and air discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1167/ - 40k
Practical Aspects of EMI Protection - Maxim [Open results in new window]
... and an electrode (shaped to simulate a finger) that discharges into the ... The test
specification
distinguishes between contact discharge and air discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1167 - 40k
Using Dallas' 1-Wire ICs in 1-Cell Li-Ion Battery Packs With Low ... [Open results in new window]
... below GND, which is possible when both the CHarge and DIScharge FETs are ... With these
5 extra
components, the DS18B20 can withstand ESD air discharges of ±20kV ...
korea.maxim-ic.com/appnotes.cfm/an_pk/122 - 25k
Fundamentals of RS-232 Serial Communications - Maxim [Open results in new window]
... ESD protection using both the human body model and the IEC 801-2 air-gap discharge
method.
... flow must be analyzed for both the charge and discharge stages of ...
korea.maxim-ic.com/appnotes.cfm/an_pk/83/ - 46k
Fundamentals of RS-232 Serial Communications - Maxim [Open results in new window]
... ESD protection using both the human body model and the IEC 801-2 air-gap discharge
method.
... flow must be analyzed for both the charge and discharge stages of ...
korea.maxim-ic.com/appnotes.cfm/an_pk/83 - 46k
Design Considerations for Data-Lump Cables - Maxim [Open results in new window]
... measures about 4.2V when fully charged and about 2.4V when fully discharged. ... 8kV,
IEC 1000-4-2,
Contact Discharge Method. ... 15kV, IEC 1000-4-2, Air Gap Discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/739/ - 42k
Design Considerations for Data-Lump Cables - Maxim [Open results in new window]
... measures about 4.2V when fully charged and about 2.4V when fully discharged. ... 8kV,
IEC 1000-4-2,
Contact Discharge Method. ... 15kV, IEC 1000-4-2, Air Gap Discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/739 - 42k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... A lamp's cold resistance is close to 0Ω, and a discharged capacitor is a ... E-field
lines
of force, which more easily ionizes the air in a corona discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/764/ - 51k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... A lamp's cold resistance is close to 0Ω, and a discharged capacitor is a ... E-field
lines
of force, which more easily ionizes the air in a corona discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/764 - 51k
Selecting the Right CMOS Analog Switch - Maxim [Open results in new window]
... result is a greater input capacitance whose charge and discharge currents dissipate ...
Body
Model, as well as the Contact and Air-Gap Discharge methods specified ...
korea.maxim-ic.com/appnotes.cfm/an_pk/638/ - 61k
Selecting the Right CMOS Analog Switch - Maxim [Open results in new window]
... result is a greater input capacitance whose charge and discharge currents dissipate ...
Body
Model, as well as the Contact and Air-Gap Discharge methods specified ...
korea.maxim-ic.com/appnotes.cfm/an_pk/638 - 61k
Murphy's Law and the Risks of Designing "Off Data Sheet" - Maxim [Open results in new window]
... The charge is discharged suddenly when we touch a ... a 1cm spark is 5000V in 50% relative
humidity
air. Figure 4. Typical winter's day electrostatic discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4429/ - 47k
Murphy's Law and the Risks of Designing "Off Data Sheet" - Maxim [Open results in new window]
... The charge is discharged suddenly when we touch a ... a 1cm spark is 5000V in 50% relative
humidity
air. Figure 4. Typical winter's day electrostatic discharge. ...
korea.maxim-ic.com/appnotes.cfm/an_pk/4429 - 47k
Designing Compact Telecom Power Supplies - Maxim [Open results in new window]
... requires that the core be discharged during the ... determines the time required to
discharge
the core. ... To reduce electromagnetic radiation, insert the air gap in ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1062 - 45k
Automotive Linear Regulators Minimize Quiescent Current - Maxim [Open results in new window]
... Even with the air conditioner fully on and the car radio playing at discothèque ... for
short
distances (as for running errands in a town) discharges much more ...
korea.maxim-ic.com/appnotes.cfm/an_pk/3928 - 37k
Flyback Transformer Design for MAX1856 SLIC Power Supplies - Maxim [Open results in new window]
... At turn-on, the total equivalent capacitance discharges through the MOSFET and current
sense ...
a good feel for the function of the core and the air gap in a ...
korea.maxim-ic.com/appnotes.cfm/an_pk/1166 - 60k
Recommended ESD Protection and Circuit Placement for the DS2438 in ... [Open results in new window]
... to protect during conditions when ground is floating (CHarge and DIScharge disabled). ...
requirements
of the IEC1000-4-2 model (±8kV direct contact, ±15kV air). ...
korea.maxim-ic.com/appnotes.cfm/an_pk/123 - 23k
Proper Layout and Component Selection Controls EMI - Maxim [Open results in new window]
... across it would remain constant during these partial charge and discharge cycles ...
the leakage
inductance results from magnetic fields in the air (because fields ...
korea.maxim-ic.com/appnotes.cfm/an_pk/716 - 59k