Practical Aspects of EMI Protection - マキシム [Open results in new window]
... and an electrode (shaped to simulate a finger) that discharges into the ... The test
specification
distinguishes between contact discharge and air discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/1167 - 40k
Using Dallas' 1-Wire ICs in 1-Cell Li-Ion Battery Packs With Low ... [Open results in new window]
... below GND, which is possible when both the CHarge and DIScharge FETs are ... With these
5 extra
components, the DS18B20 can withstand ESD air discharges of ±20kV ...
japan.maxim-ic.com/appnotes.cfm/an_pk/122 - 25k
Fundamentals of RS-232 Serial Communications - マキシム [Open results in new window]
... ESD protection using both the human body model and the IEC 801-2 air-gap discharge
method.
... flow must be analyzed for both the charge and discharge stages of ...
japan.maxim-ic.com/appnotes.cfm/an_pk/83 - 46k
Design Considerations for Data-Lump Cables - マキシム [Open results in new window]
... measures about 4.2V when fully charged and about 2.4V when fully discharged. ... 8kV,
IEC 1000-4-2,
Contact Discharge Method. ... 15kV, IEC 1000-4-2, Air Gap Discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/739 - 42k
Design Considerations for Data-Lump Cables - マキシム [Open results in new window]
... measures about 4.2V when fully charged and about 2.4V when fully discharged. ... 8kV,
IEC 1000-4-2,
Contact Discharge Method. ... 15kV, IEC 1000-4-2, Air Gap Discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/739/ - 42k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... A lamp's cold resistance is close to 0Ω, and a discharged capacitor is a ... E-field
lines
of force, which more easily ionizes the air in a corona discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/764/ - 52k
Interfacing Switches and Relays to the Real World in Real Time ... [Open results in new window]
... A lamp's cold resistance is close to 0Ω, and a discharged capacitor is a ... E-field
lines
of force, which more easily ionizes the air in a corona discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/764 - 52k
[PDF] EJ40 J [Open results in new window]
... 9 IEC 1000-4-2 COMPLIANCE LEVEL MAX TEST VOLTAGE, CONTACT DISCHARGE (kV) MAX
TEST VOLTAGE, AIR GAP
DISCHARGE (kV) 1 2 2 2 4 4 3 6 8 4 8 15 ...
pdfserv.maxim-ic.com/jp/an/AN639J.pdf
[PDF] EJ40 J [Open results in new window]
... 9 IEC 1000-4-2 COMPLIANCE LEVEL MAX TEST VOLTAGE, CONTACT DISCHARGE (kV) MAX
TEST VOLTAGE, AIR GAP
DISCHARGE (kV) 1 2 2 2 4 4 3 6 8 4 8 15 ...
pdfserv.maxim-ic.com/jp/an/A4007J.pdf
Selecting the Right CMOS Analog Switch - マキシム [Open results in new window]
... result is a greater input capacitance whose charge and discharge currents dissipate ...
Body
Model, as well as the Contact and Air-Gap Discharge methods specified ...
japan.maxim-ic.com/appnotes.cfm/an_pk/638/ - 61k
Selecting the Right CMOS Analog Switch - マキシム [Open results in new window]
... result is a greater input capacitance whose charge and discharge currents dissipate ...
Body
Model, as well as the Contact and Air-Gap Discharge methods specified ...
japan.maxim-ic.com/appnotes.cfm/an_pk/638 - 61k
Murphy's Law and the Risks of Designing "Off Data Sheet" ... [Open results in new window]
... The charge is discharged suddenly when we touch a ... a 1cm spark is 5000V in 50% relative
humidity
air. Figure 4. Typical winter's day electrostatic discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4429 - 48k
Murphy's Law and the Risks of Designing "Off Data Sheet" ... [Open results in new window]
... The charge is discharged suddenly when we touch a ... a 1cm spark is 5000V in 50% relative
humidity
air. Figure 4. Typical winter's day electrostatic discharge. ...
japan.maxim-ic.com/appnotes.cfm/an_pk/4429/ - 48k
Flyback Transformer Design for MAX1856 SLIC Power Supplies ... [Open results in new window]
... At turn-on, the total equivalent capacitance discharges through the MOSFET and current
sense ...
a good feel for the function of the core and the air gap in a ...
japan.maxim-ic.com/appnotes.cfm/an_pk/1166 - 61k
Recommended ESD Protection and Circuit Placement for the DS2438 in ... [Open results in new window]
... to protect during conditions when ground is floating (CHarge and DIScharge disabled). ...
requirements
of the IEC1000-4-2 model (±8kV direct contact, ±15kV air). ...
japan.maxim-ic.com/appnotes.cfm/an_pk/123 - 24k
[PDF] Products CD [Open results in new window]
... AIR (MOST POS.) FUR SEALING WAX ORLON HANDS LEAD ... 絶縁層の破壊といった重大な故
障を起こします。 1 Electrostatic
Discharge, Protection Test ...
pdfserv.maxim-ic.com/jp/an/AN651J.pdf
Design and Manufacture of Automotive Pressure Sensors ... [Open results in new window]
... Sensing Media: Air typically. ... vibration to hold the die in place, or a circuit design
may
have insufficient tolerance for electrostatic discharge (ESD) during ...
japan.maxim-ic.com/appnotes.cfm/an_pk/762/ - 50k
Design and Manufacture of Automotive Pressure Sensors ... [Open results in new window]
... Sensing Media: Air typically. ... vibration to hold the die in place, or a circuit design
may
have insufficient tolerance for electrostatic discharge (ESD) during ...
japan.maxim-ic.com/appnotes.cfm/an_pk/762 - 50k