[PDF] PPLICATION RIEFS [Open results in new window]
... _____ MAX3815 Features • Extends TMDS Interface Length: 0 to 50 Meters Over
24 AWG 0 to 36 Meters Over
28 AWG 0 to 30 Meters Over 30 AWG ...
pdfserv.maxim-ic.com/en/an/AN3935.pdf
[PDF] HFDN-10.0 [Open results in new window]
... The 100ft-long Belden 9207 is a 100Ω twin-axial cable that is 18-AWG with a
heavy-duty protective casing.
... It is 30-AWG and extremely lightweight. ...
pdfserv.maxim-ic.com/en/an/AN625.pdf
HFRD-28.0: 1Gbps to 8.5Gbps Active Copper SFP Cable Assembly ... [Open results in new window]
When integrated with 24 American Wire Gauge (AWG) Amphenol SpectraStrip SkewClear
cable, the completed assembly
spans up to 10 meters and operates from 1Gbps ...
www.maxim-ic.com/appnotes.cfm/an_pk/4089/ - 20k
[PDF] HFRD-39.0 REFERENCE DESIGN [Open results in new window]
... gauge. The wire gauge is usually expressed in AWG (American Wire Gauge) units;
a larger AWG number
indicates a smaller wire diameter. ...
pdfserv.maxim-ic.com/en/an/AN4352.pdf
[PDF] Flyback Transformer Design for MAX1856 SLIC Power Supplies ... [Open results in new window]
... Table 3. Transformer Wire Table AWG Wire Size Nearest SWG Wire Size Bare Conductor
Area Outside Diameter
(with Insulation) cm² x 10 -3 CIR-MIL (CM) cm inch ...
pdfserv.maxim-ic.com/en/an/AN1166.pdf
Flyback Transformer Design for MAX1856 SLIC Power Supplies - Maxim [Open results in new window]
... AWG Wire Size, Nearest SWG Wire Size, Bare Conductor Area, Outside Diameter (with
Insulation). ...
strands primary, 3, 2, 3. Primary wire gauge, 26 AWG, 30AWG, 26 AWG ...
www.maxim-ic.com/appnotes.cfm/an_pk/1166 - 60k
[PDF] HFAN-4.5.4 ‘Jitter Happens’ when a Twisted Pair is Unbalanced [Open results in new window]
... losses, and intra-pair skew. S-PARAMETERS: 15 meters, 30 AWG STP MAXIM
CONFIDENTIAL -90 -80 -70 -60
-50 -40 -30 -20 -10 0 5 0 2 ...
pdfserv.maxim-ic.com/en/an/AN3353.pdf
[PDF] Measuring Telecom Systems Against a Pulse Mask Template - AN1797 [Open results in new window]
... Maxim has T1 transceivers that can be configured for both short-haul (DSX-1) lines,
which can be up to 655ft
with 22 AWG cable, and long-haul (CSU) lines ...
pdfserv.maxim-ic.com/en/an/AN1797.pdf
[PDF] Signal Integrity vs. Transmission Rate and Cable Length for LVDS ... [Open results in new window]
... coefficients. Each output has a different set of coefficients. The cable
is unshielded Ethernet Category 5,
AWG 24, twisted-pair. We ...
pdfserv.maxim-ic.com/en/an/AN1856.pdf
Pulse Template Measurement - Maxim [Open results in new window]
... Dallas Semiconductor's T1 transceivers can be configured for both short-haul
(DSX-1) lines, which can be
up to 655 feet with 22 AWG cable, and long-haul (CSU ...
www.maxim-ic.com/appnotes.cfm/an_pk/397 - 34k
[PDF] HFRD-16.0 REFERENCE DESIGN 1Gbps to 4.25Gbps Active Copper SFP ... [Open results in new window]
... of Beaverton, Oregon. The cable is the 24 American Wire Gauge (AWG),
two-pair, SpectraStrip SkewClear
from Amphenol. Other gauge ...
pdfserv.maxim-ic.com/en/an/AN3451.pdf
[PDF] Injection Transformers for Closed-Loop DC-DC Converter Network ... [Open results in new window]
... buffered with an X10 (-20dB) FET probe, as shown in the test setup of Figure 3.
The transformer in this test
has eight turns of Teflon-insulated 24-AWG wire. ...
pdfserv.maxim-ic.com/en/an/AN3245.pdf
[PDF] HFRD-28.0 REFERENCE DESIGN 1Gbps to 8.5Gbps, Active Copper SFP ... [Open results in new window]
... SFP) copper cable assembly. When integrated with 24 American Wire Gauge
(AWG) Amphenol SpectraStrip
SkewClear cable, the ...
pdfserv.maxim-ic.com/en/an/AN4089.pdf
[PDF] Pulse Template Measurement - AN397 [Open results in new window]
... Dallas Semiconductor's T1 transceivers can be configured for both short-haul
(DSX-1) lines, which can be
up to 655 feet with 22 AWG cable, and long-haul (CSU ...
pdfserv.maxim-ic.com/en/an/AN397.pdf
Measuring Telecom Systems Against a Pulse Mask Template - Maxim [Open results in new window]
... Maxim has T1 transceivers that can be configured for both short-haul (DSX-1) lines,
which can be up to 655ft
with 22 AWG cable, and long-haul (CSU) lines ...
www.maxim-ic.com/appnotes.cfm/an_pk/1797 - 35k
[PDF] Pre-Emphasis Improves RS-485 Communications - AN643 [Open results in new window]
... These losses diminish the signal magnitude by -6dB at 4000ft (down 50%) for a
PVC-insulated, #24 AWG
twisted-pair cable with a characteristic impedance of 100V ...
pdfserv.maxim-ic.com/en/an/AN643.pdf
Pre-Emphasis Improves RS-485 Communications - Maxim [Open results in new window]
... These losses diminish the signal magnitude by -6dB at 4000ft (down 50%) for a
PVC-insulated, #24 AWG
twisted-pair cable with a characteristic impedance of 100V ...
www.maxim-ic.com/appnotes.cfm/an_pk/643 - 35k
[PDF] Understand Thermal Derating Aspects of PWM ICs to Ensure the Best ... [Open results in new window]
... IC. Thermocouple wire size can be 30 AWG or smaller, and the wires should
be routed to minimize interference
with the airflow. The ...
pdfserv.maxim-ic.com/en/an/AN4456.pdf
[PDF] HFRD-8.0 REFERENCE DESIGN 10Gbps (4x2.5Gbps) Active Copper Cable ... [Open results in new window]
... relief. See Figure 3. The cable is the 24 American Wire Gauge (AWG), eight
pair, SpectraStrip SkewClear®
from Amphenol. Other gauge ...
pdfserv.maxim-ic.com/en/an/AN3387.pdf
[PDF] HFRD-31.0 REFERENCE DESIGN [Open results in new window]
... 5.2 Construction The recommended cable is Amphenol’s 28 American Wire
Gauge (AWG), eight-pair, SpectraStrip®
SkewClear®. Other ...
pdfserv.maxim-ic.com/en/an/AN4138.pdf