*STIMULUS FOR FREQUENCY RESPONSE .INCLUDE MAX4434.FAM XTEST 1 2 3 4 5 MAX4434 VF 1 4 0 RL 1 0 10K VSIG 3 0 AC 1V VSUP 5 2 10V EG1 0 2 5 2 0.5 .AC DEC 100 1000K 300MEG .PRINT AC V(4) .PROBE .END