Maxim Current-Sense Error Budget Calculator

Please contact Tech Support if you have a question about this calculator.

Maxim CSA Device Number: Please select a MAXIM Current Sense Amplifier Device Number.
Error Budget:    
USER INPUT PARAMETERS (ENTER DATA SPECIFIC TO THE APPLICATION CIRCUIT) Enter All Values:  
Current Sense Resistor, RSENSE Ohms  
Sense Resistor Tolerance - from resistor datasheet %  
Load Current, ISENSE Amps  
Minimum Power Supply Volts  
Maximum Power Supply Volts  
Minimum Input Common Mode Voltage Volts  
Maximum Input Common Mode Voltage Volts  
DATA SHEET PARAMETERS  Enter Overrides:  
CS Amplifier Gain V/V V/V  
CS Amplifier Maximum Gain Error - default is at T = 25°C % %  
CS Amplifier Maximum Offset Error - default is at T = 25°C µV µV  
PSRR - default is at T = 25°C dB dB  
CMRR - default is at T = 25°C dB dB  
Operating Temperature Range °C    
CALCULATED CSA MEASUREMENT ERRORS   
CS Ideal Output Voltage (csiv) Volts   
Input Sense Voltage, VSENSE (csvin) Volts  
Output Referred Offset Error (oroe) Volts  
Output Referred Gain Error (orge) Volts  
Output Referred CMRR Error (orcmrre) Volts  
Output Referred PSRR Error (orpsrre) Volts  
CALCULATED ERROR DUE TO SENSE RESISTOR   
Sense Resistor Tolerance Error - ref. to Isense output (sre) Volts
Total Error - ref. to Isense output (toterror) Volts Sqrt(oroe^2+orge^2+orcmrre^2+orpsrre^2+sre^2)
ERROR BUDGET (% of Ideal Output Voltage) Error Budget = 100*(toterror/csiv)