| Member Comments |
|
|
|
|
pumpkin
- Erroneous Data Sheet
|
(no rating) 2009-06-16 |
|
Beware of the reference schematics (Fig 3 & 4): VLGND must be connected to ground.
|
|
|
|
KANA
- Re: Erroneous Data Sheet
|
(no rating) 2009-07-15 |
Calculation of compensation design (p.17ff): "Vo" is used instead of "Vout" (Vo = Vout)
Calculation of loop-gain (p.20): incorrect terms in brackets:
(1+s/2pi x f...) should be (1+s/(2 x pi x f...)) apply 5 times
|
|
|
|
Moe
- Re: Re: Erroneous Data Sheet
|
(no rating) 2009-07-28 |
|
I heard from the product manager, who says your comments are correct.
|
|
|
|
|
| Your Comments | |
|
Login or register to post a comment.
|