Feedback on http://www.maxim-ic.com/appnotes.cfm?an_pk=4117

Member Comments Avg rating: 90
  rocristian   - rocristian
2009-07-09
ok
  arielbaravalle   - dont enable osd if video signal is on befor init the max7456.
2009-10-14
I have a problem.
    if initialice the max7456 with  signal video (pal)  , dont show any data on the osd.  but  if the video signal is conected after the init of the max7456 ,  the osd work fine.
    any can help me please?
  Rob   - Re: dont enable osd if video signal is on befor init the max7456. (no rating)
2009-10-29
What do you mean by initialize? Do you mean you are configuring the registers?
The device powers up in NTSC mode and the PLL may be getting confused with a PAL signal at initialization. Try initializing with the PAL signal, removing the signal then reapplying it and see if the PLL locks on then.

For this problem I would be able to help you better if you can submit this question through our tech support link on our website.
Your Comments
Login or register to post a comment.