APPLICATION NOTE 332

DS2172 Simplified Receiver Operation

May 08, 2001

Abstract: DS2172 Bit Error Rate Tester (BERT) simplified receiver operation during repetitive pattern mode.

Operation During Repetitive Pattern Mode

PATTERN RECEIVE REGISTERS
Image 1.


Notes:

  1. All receive circuitry disabled when RDIS = 1.
  2. Clocks not shown for clarity.
6 OUT OF 64 BITS IN ERROR
ALL A & B AND PCR 2-0
Image 2.
32 CONSECUTIVE MATCHES
AT A&B




Related Parts
DS2172 Bit Error Rate Tester (BERT) Free Samples  