APPLICATION NOTE 332
DS2172 Simplified Receiver Operation
May 08, 2001
Abstract: DS2172 Bit Error Rate Tester (BERT) simplified receiver operation during repetitive pattern mode.
Operation During Repetitive Pattern Mode
PATTERN RECEIVE REGISTERS
Notes:
All receive circuitry disabled when RDIS = 1.
Clocks not shown for clarity.
6 OUT OF 64 BITS IN ERROR
ALL A & B
AND
PCR 2-0
32 CONSECUTIVE MATCHES
AT A&B