Quick-Start: Driving 7-Segment Displays with the MAX6954
Abstract:This article is how-to guide, intended as a quick learning aid for engineers considering using the MAX6954 to drive 7-segment monocolor LEDs.
The MAX6954 is a versatile display driver, capable of controlling a mix of discrete, 7-segment, 14-segment, and 16-segment LED displays through a serial interface. This application note shows a typical application and configuration for driving sixteen mono-color, 7-segment LEDs using the MAX6954.
See the MAX6954 data sheet for additional information about MAX6954 features.
A common application for the MAX6954 is driving up to sixteen 7-segment mono-color LEDs. This application note guides the user through the process of connecting the MAX6954 to 7-segment displays and configuring the internal registers to control the displays using the included hexadecimal font map.
The MAX6954 utilizes a multiplex technique that reduces driver pin count by using ports alternately as cathode and anode drivers. This differs from the standard LED multiplex connection, which uses separate driver pins for anodes and cathodes. The technique is discussed in "Charlieplexing - Reduced Pin-Count LED Display Multiplexing". Table 1 lists the connection scheme for 7-segment digits that is compatible with the MAX6954 multiplex scheme and the built in hexadecimal font map. The letters in Table 1 correspond to the segment labels shown in Figure 2. Figure 1 illustrates a sixteen digit, 7-segment application circuit for the MAX6954.
Table 1. Connection Scheme for Sixteen 7-Segment Digits
Digit
O0
O1
O2
O3
O4
O5
O6
O7
O8
O9
O10
O11
O12
O13
O14
O15
O16
O17
O18
0 0a
CC0
1a
1b
1c
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
1, 1a
CC1
1a
1b
1c
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
2, 2a
1a
CC2
1b
1c
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
3 3a
1a
CC3
1b
1c
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
4 4a
1a
1b
1c
CC4
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
5 5a
1a
1b
1c
CC5
1d
1dp
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
6, 6a
1a
1b
1c
1d
1dp
CC6
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
7, 7a
1a
1b
1c
1d
1dp
CC7
1e
1f
1g
2a
2b
2c
2d
2e
2f
2g
2dp
Display test mode can be used to verify connections after connecting the MAX6954 to 7-segment displays. Display test mode overrides, but does not alter, all control and digit registers and turns all segments on. Enable display test mode by writing 0x01 to register 0x07. If a segment does not light in display test mode this indicates a connection problem that should be investigated. Write 0x00 to register 0x07 to exit display test mode.
Figure 2. Segment labeling for 7-aegment displays.
After verification of the connections between the MAX6954 and the 7-segment displays the device must be configured for operation with 7-segment displays. Table 2 contains a list of the initial power-up states of important MAX6954 registers. When power is first applied to the MAX6954 the device is in shutdown mode, all digits are blanked, the 7-segment font map is selected and the device is set to scan the maximum number of digits. The default decode mode (0x01) and digit type (0x0C) register settings are correct for 7-segment applications.
Shutdown enabled, blink disabled, blink speed is slow
0x04
0
0
X
X
0
0
0
0
Display Test
Normal operation (display test disabled)
0x07
X
X
X
X
X
X
X
0
Digit Type
Digits 0 through 7 are 7 segment digits
0x0C
0
0
0
0
0
0
0
0
Intensity10
1/16 (min on), digits 1 and 0
0x10
0
0
0
0
0
0
0
0
Intensity32
1/16 (min on), digits 3 and 2
0x11
0
0
0
0
0
0
0
0
Intensity54
1/16 (min on), digits 5 and 4
0x12
0
0
0
0
0
0
0
0
Intensity76
1/16 (min on), digits 7 and 6
0x13
0
0
0
0
0
0
0
0
Intensity10a
1/16 (min on), digits 1a and 0a
0x14
0
0
0
0
0
0
0
0
Intensity32a
1/16 (min on), digits 3a and 2a
0x15
0
0
0
0
0
0
0
0
Intensity54a
1/16 (min on), digits 5a and 4a
0x16
0
0
0
0
0
0
0
0
Intensity76a
1/16 (min on), digits 7a and 6a
0x17
0
0
0
0
0
0
0
0
Digit 0
Blank digit, both planes
0x60
0
0
1
0
0
0
0
0
Digit 1
Blank digit, both planes
0x61
0
0
1
0
0
0
0
0
Digit 2
Blank digit, both planes
0x62
0
0
1
0
0
0
0
0
Digit 3
Blank digit, both planes
0x63
0
0
1
0
0
0
0
0
Digit 4
Blank digit, both planes
0x64
0
0
1
0
0
0
0
0
Digit 5
Blank digit, both planes
0x65
0
0
1
0
0
0
0
0
Digit 6
Blank digit, both planes
0x66
0
0
1
0
0
0
0
0
Digit 7
Blank digit, both planes
0x67
0
0
1
0
0
0
0
0
Digit 0a
Blank digit, both planes
0x68
0
0
1
0
0
0
0
0
Digit 1a
Blank digit, both planes
0x69
0
0
1
0
0
0
0
0
Digit 2a
Blank digit, both planes
0x6A
0
0
1
0
0
0
0
0
Digit 3a
Blank digit, both planes
0x6B
0
0
1
0
0
0
0
0
Digit 4a
Blank digit, both planes
0x6C
0
0
1
0
0
0
0
0
Digit 5a
Blank digit, both planes
0x6D
0
0
1
0
0
0
0
0
Digit 6a
Blank digit, both planes
0x6E
0
0
1
0
0
0
0
0
Digit 7a
Blank digit, both planes
0x6F
0
0
1
0
0
0
0
0
The configuration register (0x01) is used to enter and exit shutdown, control the blink function, globally clear the digit data and to select between global or digit-by-digit control of intensity. The configuration register contains 7 bits (Table 3):
S bit selects shutdown or normal operation (read/write).
B bit selects the blink rate (read/write).
E bit globally enables or disables the blink function (read/write).
T bit resets the blink timing (data is not stored-transient bit).
R bit globally clears the digit data for both planes P0 and P1 for ALL digits (data is not stored-transient bit).
I bit selects between global or digit-by-digit control of intensity (read/write).
P bit returns the current phase of the blink timing (read only-a write to this bit is ignored).
Table 3. Configuration Register Format
CONFIGURATION REGISTER DATA BIT
DATA BIT LABEL
STATE
FUNCTION
D7
P
0
P1 Blink Phase
D6
I
0
Intensity for all digits is controlled by one setting in the Global Intensity Register
1
Intensity for digits is controlled by the individual settings in the Intensity10 through Intensity76a registers.
D5
R
0
Digit data for both planes P0 and P1 are unaffected
1
Digit data for both planes P0 and P1 are cleared on the rising edge of active-low CS
D4
T
0
Blink timing counters are unaffected.
1
Blink timing counters are reset on the rising edge of active-low CS.
D3
E
0
Blink function disabled
1
Blink function enabled
D2
B
0
Slow Blinking. Segments blink on for 1s, off for 1s with fOSC = 4MHz.
1
Fast Blinking. Segments blink on for 0.5s, off for 0.5s with fOSC = 4MHz.
D1
X
X
Don't care
D0
S
0
Shutdown
1
Normal Operation
Enable the display driver with global intensity control and without blinking by writing 0x01 to register 0x04. The internal oscillator powers as the MAX6954 exits shutdown and the oscillator output is available at OSC_OUT. Notice that the 7-segment displays remain blank, as the power-up state of digit control registers 0x60 to 0x6F is 0x20 or no segments lit (see Table 2 and Figure 3).
Figure 3. 7-segment display font map.
The MAX6954 includes a hexadecimal font map for 7-segment displays. Seven bits represent the hexadecimal font map; an 8th bit is used to select whether the decimal point (DP) is lit (Table 4). Digit registers are implemented with two planes, P0 and P1. Each digit is represented by 2 bytes of memory, 1 byte in plane P0 and the other in plane P1 (see Table 7). The digit registers are mapped so that a digit's data can be updated in plane P0 (registers 0x20 through 0x2F), plane P1 (registers 0x40 through 0x4F), or both planes simultaneously (registers 0x60 through 0x6F). The data in the digit registers does not control the digit segments directly for 7-segment displays. Instead, the register data is used to address a character generator that stores the data for the font (Figure 3). The lower 7 bits of the digit data (D6 to D0) select the character from the font. The most significant bit of the register data (D7) controls the DP segment of the digits; it is set to 1 to light DP, and to 0 to leave DP unlit.
Table 4. Digit Type Data Register Format
MODE
ADDRESS CODE (HEX)
REGISTER DATA
D7
D6
D5
D4
D3
D2
D1
D0
7-segment mode, writing digit data to use font map data with decimal place unlit
0x20 to 0x2F 0x40 to 0x4F 0x60 to 0x6F
0
Bits D6 to D0 select font character
7-segment mode, writing digit data to use font map data with decimal place lit
0x20 to 0x2F 0x40 to 0x4F 0x60 to 0x6F
1
Bits D6 to D0 select font character
If the blink function is disabled through the Blink Enable Bit E (Table 3) in the configuration register, then the digit register data in plane P0 is used to multiplex the display. The digit register data in P1 is not used. If the blink function is enabled, then the digit register data in both plane P0 and plane P1 are alternately used to multiplex the display. Blinking is achieved by multiplexing the LED display using data plane P0 and plane P1 on alternate phases of the blink clock.
As an example let's display the phone number for Maxim/Dallas Direct: 1 800 629 4642, using the MAX6954. We disabled the blink functionality when we programmed the configuration register, so data can be written to the 0x20 through 0x2F registers to control digit 0 through digit 7a, respectively. Using the font map in Figure 3 determine the code equivalent for each character:
Table 5. Call 800.629.4642 Example
REGISTER ADDRESS (HEX)
DIGIT
CHARACTER
FONT MAP EQUIVALENT CODE
DECIMAL
HEX
0x20
0
C
0000 1100
0x0C
0x28
0a
A
0000 1001
0x0A
0x21
1
1
0000 0001
0x01
0x29
1a
1
0000 0001
0x01
0x23
3
8
0000 1000
0x08
0x2B
3a
0
0000 0000
0x00
0x24
4
0
1000 0000
0x80
0x2C
4a
6
0000 0110
0x06
0x25
5
2
0000 0010
0x02
0x2D
5a
9
1000 1001
0x89
0x26
6
4
0000 0100
0x04
0x2E
6a
6
0000 0110
0x06
0x27
7
4
0000 0100
0x04
0x2F
7a
2
0000 0010
0x02
Adjust the intensity of the displays by writing to register 0x02, the global intensity control register. Intensity may be adjusted between 0x00 (minimum on, 1/16 current) and 0xFF (maximum on, 15/16 current). Digital control of display brightness can also be managed individually for each digit. For full details about adjusting digit intensity and other advanced features such as GPIO and key-scan, refer to the MAX6954 data sheet.
Table 6. Quick-Start Example Command Summary
REGISTER (HEX)
COMMAND (HEX)
FUNCTION
0x07
0x01
Enter display test mode
0x07
0x00
Exit display test mode
0x04
0x01
Exit shutdown mode, disable blinking and select global intensity control
Automatic Updates
Would you like to be automatically notified when new application notes are published in your areas of interest? Sign up for EE-Mail™.